Position control for low-play doors / casings on hazardous machinery
Contactless encoded electronic sensor with relay
Category 1 total safety management without an external controller
Level of performance without an external controller: PL = c
Level of performance with AWAX controller: up to PL = e
Warranty: 3 years
Technical description
- Safety category without an external controller: 1.
- Cycle before dangerous failure: B10d = 2,000,000 at 100mA.
- Max. activation distance: 6 mm, 2 mm hysteresis.
- Safety contacts/diagnostics (7SSR24V/6M): 2 x NO 1A/48V redundant / 1 x PNP 1A auxiliary.
- Detection encoding: mono-code inviolable.
- Indication: LED indicating code absence.
- Reset: automatic.
- Attachment: 2 M30 nuts provided.
- Mounting position: 1.
- Material: CuNi (Cupronickel).
- Electrical connection: 6m cable.
- Water resistance: IP 67.
- Temperature: -25°C to +60°C.
- Marking: label + serial no. for traceability.