Power supply : DC 12~30V
Maximum current : 150mA/12V; 80mA/24V; 60mA/30V
Button :
Insulation resistance : >100Mohm
Shock resistance voltage : 2500V
Life cycle management >250,000 Hours
B10d : 250 000
Number of hours of use per day (Hop) : 16h
Number of days of use per year : (Dop) : 320 days
Time between 2 consecutive starts (Tc) : 3h either 10800 seconds
Calculate of the MTTFd :
Nop = (Hop*Dop*3600)/Tc
MTTFd = B10d/(0.1*Nop) = 1465 years
Contact NC Y W-E01 IDEC
YM1B-V TÜV / UL / CE / CCC
12 à 30 VDC / 2A
Indicator color : Fixed green & Flashing red
Other colours available as an option : Red, Green, Yellow (fixed or flashing version)
LED Flashing frequency : 1.6HZ à 50% duty cycle
Input efficiency : >7.2V Input impedance 10K
Electrical : Protection against overcurrents, overvoltages, connection reversals
IP : IEC IP65
Connection : 1 meter cable ou Connector M12 male QD with cable 30 cm option
Work environment : – 20 ° C to 50 ° C ( – 4 ° F to 122 ° F) Humidity : 95% at 50 ° C
Materal :
- Button and Base : ABS (70%) + Polycarbonate (30%)
- Coverage : Polycarbonate
Vibration resistance : 10Hz to 500Hz, amplitude 0.35mm acceleration 50m/s2
Shock resistance : 150 m / s2